1. Bridge |
1). Road bridge |
- Superstructure type suspension bridge, cable-stayed bridge, arch bridge and truss bridge
- Bridges up to 50 meters above Gyeongganjang (except for span bridges)
- A bridge over 500 meters in length
- Covering structure with a width of 12 meters or more and an extension of 500 meters or more
|
- Gyeongganjang span bridge over 50 meters
- A bridge extending over 100 meters as a bridge that does not fall under one category of facilities
- Covering structure with a width of 6 meters or more as a covering structure that does not correspond to one type of facility and extending 100 meters or more
|
2). Railway bridge |
- High-speed railway bridge
- City Rail Bridge and Viaduct
- A bridge whose superstructure type is truss bridge and arch bridge
- A bridge over 500 meters in length
|
- A bridge extending over 100 meters as a bridge that does not fall under one category of facilities
|
2. Tunnel |
1). Road tunnel |
- More than 1,000 meters of tunnel
- 3 or more tunnels
- Underground driveway with a tunnel section of 500 meters or more
|
- As a tunnel that does not fall under one type of facility, highway national highway, general national highway, special degree and wide area city tunne
- A region with a length of 300 meters or more was tried as a tunnel that does not correspond to one type of facility, but a tunnel with an island and composition
- As an underground car road that does not fall under one type of facility, an underground car road with a tunnel section extending over 100 meters
|
2). Railway tunnel |
- High-speed railway tunnel
- Urban railway tunnel
- More than 1,000 meters of tunnel
|
- As a tunnel that does not fall under one type of facility, highway national highway, general national highway, special degree and wide area city tunnel
|
3. Port |
1). Lock |
|
- |
2). Breakwater, wave preparation and revetment |
- Breakwater more than 1,000 meters in length
|
- Breakwater more than 500 meters as a breakwater which does not correspond to 1 type facilities
- Wave formulation over 500 meters in length
- Revetment over 500 meters extending the function of the breakwater
|
3). Mooring facility |
- One Yu Buoy (BUOY) mooring facility (including a submarine pipeline, which is an incidental facility) as a loading and unloading facility for ships of -200,000 tons or more
- Pile structure mooring facilities (only facilities of 50,000 ton or more)
|
- Wonyu bui (BUOY) type mooring facilities of 10,000 tons or more (including submarine pipelines as incidental facilities) as WonYu bui (BUOY) type mooring facilities that do not fall under a type 1 facility
- A mooring facility with a pile structure of 10,000 tons or more as a mooring facility with a pile structure that does not fall under the category 1 facility
- Gravity type mooring facilities of over 10,000 tons
|
4. Dam |
- |
- A multipurpose dam, a power generation Jondem, a flood dedicated dam and a water dedicated dam with a capacity of 10,000 tons or more
|
- A dam dedicated to local water supply and a dam dedicated to water only with a capacity of 10,000 tons or more
|
5. Building |
1). Shared housing |
- |
- Shared housing on the 16th floor and above
|
2). Buildings other than communal housing |
- Building 21 floors or more or a total area of 50,000 square meters or more
- A total of more than 30,000 square meters of railway station facilities and viewing area
- Underpass shopping street with a total floor area of over 10,000 square meters (including underground walk area)
|
- As a building which does not correspond to 1 kind facility, a building of 16 floors or more or a total area of 30,000 square meters or more
- High-speed railways, urban railways and regional railway station facilities as railway station facilities that do not fall under the category 1 facility
- As a building that does not correspond to a type 1 facility, a plurality of used buildings, an exhibition area with a total area of over 5,000 square meters, a general railway history, an airport government building, and a port passenger terminal
- Underpass shopping street with a total area of 5000 square meters or more (including underground footpath area) as an underpass shopping street that does not fall under the category 1 facility
|
6. River |
1). Movable rod |
- Movable scissors
- Seawall with over 80 million tons of accepted jaws
|
- Seawalls accepted as seawalls that do not fall under one category of facilities, with a combined quantity of 10,000 tons or more
|
2). Lock and lock |
- Locks and gates of national rivers in special cities and regional cities
|
- Locks and locks of national rivers as locks and locks that do not fall under one type of facility
- Special, wide-area city, special autonomous city and local river sluice and lock in the city
|
3). Levee |
- |
- Banks of national rivers (including customs clearance (conducted facilities) and revetment)
|
4). baud |
- A multi-functional cross with a height of 5 meters or more installed in national rivers
|
- Multi-function installed in rivers of the country as a protection that does not fall under a type 1 facility
|
5). Drainage pump station |
- Drainage pumping stations for national rivers in special cities and regional cities
|
- A drainage pump station of a national river as a drainage pump station that does not fall under the category 1 facility
- Special, wide-area city, special drainage city and drainage pump stations of local rivers in the city
|
7. Water and sewage |
1) Water supply |
- Wide area water supply
- Can also be used industrially
- 1 Local water supply with a supply capacity of 30,000 tons or more
|
- Local water supply which does not correspond to -1 kind facility
|
2). Sewerage |
- |
- Public sewage treatment facilities (only facilities with a maximum capacity of 500 tons or more per day
|
8. Retaining wall and cut slope |
- |
- |
- Retaining wall of 100 meters or more in total of parts exposed 5 meters or more in height from the ground
- A cut slope with a single horizontal extension of 100 meters or more, as a cut section including 30 meters or more in height (vertical height) from the ground (height from the top of the retaining wall if there is a retaining wall)
|
9. Joint groove |
- |
- |
|